Need help selecting the right product for your application?
Explore our wide range of high-quality products engineered for precision and durability.
Protect temperature sensors from process conditions while enabling reliable and accurate temperature measurement. Elite Flow Engineering offers thermowells designed for different pressure, temperature, flow and installation requirements across industrial applications.
Description:
The outer diameter gradually decreases from the base (process connection) to the tip.
Real-Life Application:
The standard for demanding processes. Ideal for high-pressure, high-velocity, and vibrating applications (pipelines, refineries, power plants).
Materials:
SS316, SS304 and SS316L
Technical Specifications:
Parameter | Tapered |
Construction | One-piece, drilled from solid bar stock |
Process connection † | Threaded (NPT / BSP), flanged, weld-in |
Thread sizes † | 1/2″, 3/4″, 1″ NPT (M) |
Flange size and rating † | 1″ to 2″; Class 150 / 300 / 600 |
Bore (sensor size) † | 0.260″ (6.6 mm) for 1/4″ sensor; 0.385″ (9.8 mm) for 3/8″ sensor |
Insertion length (U) † | 50 to 600 mm (2″ to 24″), made to order |
Lagging / extension (T) † | Optional, for insulated lines |
Tip form | Closed tip |
Wetted surface finish † | 0.8 µm Ra (32 µin) typical |
Pressure rating † | Per flange class or thread rating, and material |
Temperature limit † | Up to 650 °C, subject to pressure derating |
Vibration / vortex resistance | Superior: resists bending from flow- induced vibration |
Design reference † | ASME PTC 19.3 TW; DIN 43772 |
Testing † | Hydrostatic test and dimensional check; PMI on request |
Documents | EN 10204 3.1 material test certificate with heat number traceability |
Description:
The thermowell has a uniform outer diameter along its entire insertion length. This is the most basic design.
Real-Life Application:
Best for low-pressure, low-velocity processes. Commonly used in tanks, boilers, and utility lines with minimal flow.
Materials:
SS316, SS304 and SS316L
Technical Specifications:
Parameter | Flanged (Straight) |
Construction | One-piece, drilled from solid bar stock |
Process connection † | Flanged (ASME B16.5, raised face) |
Thread sizes † | n/a |
Flange size and rating † | 1″ to 2″; Class 150 / 300 / 600 |
Bore (sensor size) † | 0.260″ (6.6 mm) for 1/4″ sensor; 0.385″ (9.8 mm) for 3/8″ sensor |
Insertion length (U) † | 50 to 600 mm (2″ to 24″), made to order |
Lagging / extension (T) † | Optional |
Tip form | Closed tip |
Wetted surface finish † | 0.8 µm Ra (32 µin) typical |
Pressure rating † | Per ASME B16.5 flange class and material |
Temperature limit † | Up to 650 °C, subject to pressure derating |
Vibration / vortex resistance | Lowest |
Design reference † | ASME PTC 19.3 TW; DIN 43772 |
Testing † | Hydrostatic test and dimensional check; PMI on request |
Documents | EN 10204 3.1 material test certificate with heat number traceability |
Description:
Has a larger diameter at the base which “steps” down to a smaller diameter for the rest of the length, usually near the tip.
Real-Life Application:
Used when the fastest possible response time is the most critical factor. Common in process control loops and laboratory settings.
Materials:
SS316, SS304 and SS316L
Technical Specifications:
Parameter | Stepped |
Construction | One-piece, drilled from solid bar stock |
Process connection † | Threaded (NPT / BSP), flanged, weld-in |
Thread sizes † | 1/2″, 3/4″, 1″ NPT (M) |
Flange size and rating † | 1″ to 2″; Class 150 / 300 / 600 |
Bore (sensor size) † | 0.260″ (6.6 mm) for 1/4″ sensor; 0.385″ (9.8 mm) for 3/8″ sensor |
Insertion length (U) † | 50 to 600 mm (2″ to 24″), made to order |
Lagging / extension (T) † | Optional |
Tip form | Closed tip |
Wetted surface finish † | 0.8 µm Ra (32 µin) typical |
Pressure rating † | Per flange class or thread rating, and material |
Temperature limit † | Up to 650 °C, subject to pressure derating |
Vibration / vortex resistance | Moderate (check wake frequency for high-velocity service) |
Design reference † | ASME PTC 19.3 TW; DIN 43772 |
Testing † | Hydrostatic test and dimensional check; PMI on request |
Documents | EN 10204 3.1 material test certificate with heat number traceability |
Complete your temperature measurement system with reliable accessories designed for accurate monitoring, sensor protection and dependable operation in industrial environments.
Description:
Bimetal dial thermometers provide direct temperature indication through a clear analog dial. Their robust construction makes them suitable for continuous temperature monitoring in industrial environments.
Applications:
Commonly used for temperature measurement in pipelines, tanks, process equipment, HVAC systems, utilities and general industrial applications.
Tell us what you need. Our team can help you find the right valves, fittings, instrumentation and flow control products for your application.